Extinguisher Filling Equipment
Fire Alarm System
Sprinkler System
Extinguisher
Fireman Outfits
Fire Pump Set
Fire Suppression System
Hose Reel & Cabinet
Extinguisher Fittings
Fire Robot
Fire Hose System
Inert Gas System 200BAR / 300BAR

Inert Gas System 200BAR / 300BAR

FEATURE

MADEL NO: SNG21-05

 Synert Gas System: The Latest Technology:

SYNERGY has introduced an improvement in systems using IG-01,IG-55,IG-100,IG-541 as the extinguishing agent with the latest technology, providing benefits to the facility itself and the protected enclosure.

 

This innovative technology enables to optimize the design of the firefighting  system  with  IG-01,IG-55,IG-100,IG-541  as  the discharge pressure and flow control allow users to reduce the size of tubing needed for proper distribution of the agent and reduce overpressure that take place in the protected enclosure, minimizing the area for the relief of excess pressure.

 

SYNERT systems are designed to suppress fires involving class A, B and C hazards. The systems are designed to be total flooding and consist of a fixed supply of agent connected to a piping system with nozzles to direct the agent into an enclosed hazard. Inert gas extinguishes fires by lowering the oxygen content below the level that supports combustion. In simple terms if the oxygen content of the atmosphere is reduced to a level below 15%, most ordinary combustibles will not burn. Since SYNERT agents are stored as a gas, it discharges as an invisible gas, allowing people to safely exit a protected space without obscured vision.

 

SYNERT gas systems are particularly valuable in extinguishing fires in enclosures containing hazards or equipment where a clean, electrically non-conductive medium is essential or where the cleaning up of foam, water or powder would be problematic.


 




0.00
0.00
  

FEATURE

MADEL NO: SNG21-05

 Synert Gas System: The Latest Technology:

SYNERGY has introduced an improvement in systems using IG-01,IG-55,IG-100,IG-541 as the extinguishing agent with the latest technology, providing benefits to the facility itself and the protected enclosure.

 

This innovative technology enables to optimize the design of the firefighting  system  with  IG-01,IG-55,IG-100,IG-541  as  the discharge pressure and flow control allow users to reduce the size of tubing needed for proper distribution of the agent and reduce overpressure that take place in the protected enclosure, minimizing the area for the relief of excess pressure.

 

SYNERT systems are designed to suppress fires involving class A, B and C hazards. The systems are designed to be total flooding and consist of a fixed supply of agent connected to a piping system with nozzles to direct the agent into an enclosed hazard. Inert gas extinguishes fires by lowering the oxygen content below the level that supports combustion. In simple terms if the oxygen content of the atmosphere is reduced to a level below 15%, most ordinary combustibles will not burn. Since SYNERT agents are stored as a gas, it discharges as an invisible gas, allowing people to safely exit a protected space without obscured vision.

 

SYNERT gas systems are particularly valuable in extinguishing fires in enclosures containing hazards or equipment where a clean, electrically non-conductive medium is essential or where the cleaning up of foam, water or powder would be problematic.


 





















  Synert 200BAR / 300BAR Inert Gas System:
SYNERT GAS SYSTEM containers allow you to protect single- or multiple-hazard areas typically requiring less floor space than other inert gas systems.


  Synert Agent Specification:



  How Is It Actuated?:
The extinguishing principle of inert gases focuses on reducing oxygen concentration in the affected zone. When a fire starts SYNERT Gases rapidly penetrates the area and reduces the oxygen level percentage from the usual level of 21% to a limit that fluctuates between 13% and 11%, the amount sufficient for combustion to stop and to be safe for the people in the room. Due to the stratification of the gases, protection is achieved throughout the space, regardless of how high the ceiling is. During its discharge, there is excellent visibility and, since it leaves no residue, there are no destructive effects to the equipment, which will continue functioning normally and, of course, there will be nothing to clean up.



  Maximum Protection,Minimum Storage:
SYNERT GAS SYSTEM containers allow you to protect single- or multiple-hazard areas typically requiring less floor space than other inert gas systems.


Think of the cost savings!

You no longer need to purchase, install and maintain several individual protection systems for your multi-risk facility. One SYNERT GAS SYSTEM does it all.


Temperature Range

The components are designed and tested to operate in the temperature range -20 °C to 50 °C or as stated in separate component listings.


SYNERT Agents

Under normal conditions SYNERT agents are odourless and colourless gas.

SYNERT Gases do not support combustion, nor have an impact on the ozone layer, and have no global warming potential. Inert Gases are supplied as under:



Storage containers are designed to hold agent in gaseous form at a nominal pressure of 200 bar or 300 bar at 15 °C.

Handling and Installation of SYNERT equipment should only be carried out by persons experienced in dealing with this type of equipment. The following specification applies to SYNERT agents.